Gold Member Since 2017
Audited Supplier
Yuyao Yinhuan Flowmeter Co., Ltd.

Flowmeter, Flow Meter, Electromagnetic Flowmeter manufacturer / supplier in China, offering Za Intelligent Converter Flange Divided Type Electromagnetic Flowmeter, Lzt-S Plastic Tube Flowmeter, Lzt Pipeline Type Flowmeter and so on.

(/ )

Supplier Homepage Product Electromagnetic Flowmeter Flange Divided Type Za Intelligent Converter Flange Divided Type Electromagnetic Flowmeter

Za Intelligent Converter Flange Divided Type Electromagnetic Flowmeter

FOB Price: Get Latest Price
Min. Order: 1 Piece
Port: Ningbo, China
Production Capacity: 100000
Payment Terms: L/C

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: LD/F/ZA
  • Main Application: Water, Wastewater, Corrosive Liquid/Gas
  • Sensor: Tube/Flange
  • Type: Electromagnetic Flow Meter
  • Measuring Principle: Electrical Principles
  • Certification: SGS, ISO
  • Electrode: 316L/Tuc/Ti/Hc/Hb/Ta/PT
  • Transport Package: Carton/ Wooden Cases
  • Origin: China Zhejiang Yuyao
  • Accuracy: ±0.2-0.5%
  • Size: Dn10-2200
  • Application: Industrial Production
  • Measuring Media: Liquid
  • Measurement Object: Closed Pipeline
  • Pressure: 0.25/0.6/1/1.6/4 MPa
  • Trademark: yinhuan
  • Specification: DN10-2200
  • HS Code: 902610000
Product Description
LD series electromagnetic flowmeter consists of sensors and converters in two parts. It is based on Faraday's law of electromagnetic induction and is used to measure the volumetric flow of conductive liquids with a conductivity greater than 5 μS / cm. It is an inductive instrument for measuring the volume flow of conductive media. In addition to measuring the general volume of conductive liquid flow, but also for measuring strong acid, alkali and other strong corrosive liquids and slurry, pulp, pulp and other liquid-solid two-phase suspension of uniform volume of liquid flow. Widely used in petroleum, chemical, metallurgy, textile, paper, environmental protection, food and other industrial sectors and municipal management, water conservancy construction, river dredging and other areas of flow measurement.

Product performance standards: JB/T9248-1999(Industry Standard)
Flange standard:       GB/T9119-2000(National standard)
          GB/T9115.1-2000(National standard with neck flangeDN700mm)

Features:
1. Measurement of non-blocking flow tube, the pressure loss is zero, not easy to block.
2. As long as a reasonable choice of electrode and lining materials, you can achieve corrosion resistance, wear resistance, temperature requirements.
3. Measurement results with the liquid pressure, temperature, density, viscosity, conductivity (not less than the minimum conductivity) and other physical parameters have nothing to do, from the environment, so high accuracy, stable and reliable.
4. The use of modern analog signal conversion technology and high-performance ultra-large-scale integrated chip, the signal isolation, filtering, amplification and digital processing. Accurate display of measurement results.
5. Automatic monitoring and correction of parameters that affect the measurement results, such as zero drift correction, the use of sub-flow coefficient of the whole range of setting and correction, thus expanding the measurement range, improve the intelligence and measurement accuracy, greatly improved Stability.
6. With the measured value of power protection and over-range alarm function, the flow of fluid within the sensor can be set, so the sensor is not restricted by the direction of liquid flow can be achieved two-way flow measurement.
7. With a backlit dot matrix double flow display, also shows the instantaneous flow, cumulative flow, and can display the working status, parameters, units of measurement and so on.
8. Electromagnetic flowmeter wide range (maximum flow / minimum flow), the normal scope of application 20: 1, generally 30: 1 or more.
9. Meter configuration has a variety of output functions, with the computer, unit combination instrumentation, to complete the printing, communication and networking requirements.

Output:1. Pulse,DC4~20mA (four-wire)
            2. Pulse,DC4~20mA (four-wire),RS485(Except FOX head)
       3. Pulse,DC4~20mA (four-wire),Hart

Power Supply:1. AC220V, power 12w
              2. DC24V,power 12w
              3. ZD lithium battery(3.6V)5*19AH


Za Intelligent Converter Flange Divided Type Electromagnetic Flowmeter

Za Intelligent Converter Flange Divided Type Electromagnetic Flowmeter
Za Intelligent Converter Flange Divided Type Electromagnetic Flowmeter

Za Intelligent Converter Flange Divided Type Electromagnetic Flowmeter


Za Intelligent Converter Flange Divided Type Electromagnetic Flowmeter



Za Intelligent Converter Flange Divided Type Electromagnetic Flowmeter
Send your message to this supplier
Avatar
Mr. Shi
Sales Manager
*From:
To: Mr. Shi
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now